Peptas Instruments / Laboratory lyophiliser
Peptas Instruments LY-1004 Laboratory freeze dryer with round chamber and temperature-controlled shelves, 0.3 m²
Laboratory lyophiliser
Made to order. Quote on request.
Request a quotation Explore specificationsKey features
- Drying area: 0.3 m²Nominal; Ordinary shelf configuration. Configuration-specific
- Water capture capacity: 6 kg/batchNominal; Per batch, as stated; not a daily rate. Configuration-specific
- Bottle capacity, Ø12 mm bottles: 1950 bottlesNominal; Small glass bottles of the stated diameter, as counted by the source. Configuration-specific
Technical detail
Specifications
Values are shown with their stated basis and source.
| Parameter | Specification | Basis / conditions | Source |
|---|---|---|---|
| Drying area | 0.3 m² | Nominal; Ordinary shelf configuration. Configuration-specific | Source 1 · Shelf series table / ordinary configuration / drying area |
| Water capture capacity | 6 kg/batch | Nominal; Per batch, as stated; not a daily rate. Configuration-specific | Source 1 · Shelf series table / ordinary configuration / water capture |
| Bottle capacity, Ø12 mm bottles | 1950 bottles | Nominal; Small glass bottles of the stated diameter, as counted by the source. Configuration-specific | Source 1 · Shelf series table / ordinary configuration / bottle quantity / 12 mm |
| Bottle capacity, Ø16 mm bottles | 1160 bottles | Nominal; Small glass bottles of the stated diameter, as counted by the source. Configuration-specific | Source 1 · Shelf series table / ordinary configuration / bottle quantity / 16 mm |
| Bottle capacity, Ø22 mm bottles | 615 bottles | Nominal; Small glass bottles of the stated diameter, as counted by the source. Configuration-specific | Source 1 · Shelf series table / ordinary configuration / bottle quantity / 22 mm |
| Shelf loading capacity | 3 L | Nominal; Configuration-specific | Source 1 · Shelf series table / ordinary configuration / shelf load capacity |
| Shelf width | 240 mm | Nominal; Shelf length is not stated consistently by the sources and is omitted. Configuration-specific | Source 1 · Shelf series table / ordinary configuration / shelf width |
| Shelf spacing | 70 mm | Nominal; Configuration-specific | Source 1 · Shelf series table / ordinary configuration / shelf distance |
| Shelf temperature range | -40–70 °C | Nominal; No load; stated by the source as a theoretical value. Configuration-specific | Source 1 · Shelf series table / ordinary configuration / shelf temperature range |
| Condenser temperature | -56 °C | Maximum; No load. Configuration-specific | Source 1 · Shelf series table / ordinary configuration / condenser lowest temperature |
| Drying chamber shape | Round | Nominal; Configuration-specific | Source 2 · Product overview / shelf series block heading |
Specification sources
- Specification source 1Document SHA-256:
fc83603b98f6af941e00ade78a343cbba1461cc7409deb876357f1a82ba404f4 - Specification source 2Document SHA-256:
09e7a915d1c2fbb92d94094193676295724b83750192678cc3e99e5b30eeb5d9
Source documents are supplied with the quotation on request.
Configure your system
Options
Discuss your requirements when requesting a quotation.
Complete your setup
Accessories
Discuss your requirements when requesting a quotation.
Your requirements
Discuss your configuration
Include the model, required configuration and accessories in your enquiry.