Peptas Instruments / Low-pressure liquid chromatography system
Peptas Instruments LPC-1002 Bio-inert low-pressure liquid chromatography system, 300 mL/min class
Low-pressure liquid chromatography system
Made to order. Quote on request.
Request a quotation Explore specificationsKey features
- Mobile-phase inlet valve: 4 channelsNominal; Configuration-specific
- Pump: PEEK pump of bio-inert material with self-flushing pump headNominal; Configuration-specific
- Flow-rate range: 0–300 mL/minNominal; Configuration-specific
Technical detail
Specifications
Values are shown with their stated basis and source.
| Parameter | Specification | Basis / conditions | Source |
|---|---|---|---|
| Mobile-phase inlet valve | 4 channels | Nominal; Configuration-specific | Source 1 · Configuration table / mobile-phase selection / inlet valve / selected column |
| Pump | PEEK pump of bio-inert material with self-flushing pump head | Nominal; Configuration-specific | Source 1 · Configuration table / solvent delivery / pump |
| Flow-rate range | 0–300 mL/min | Nominal; Configuration-specific | Source 1 · Configuration table / solvent delivery / flow range / selected column |
| Flow accuracy | ±1 % | Nominal; Test conditions are not stated by the source. Configuration-specific | Source 1 · Configuration table / solvent delivery / flow accuracy / selected column |
| Gradient modes | Isocratic and linear; gradient ratio adjustable during a run | Nominal; Configuration-specific | Source 1 · Configuration table / solvent delivery / gradient type |
| Mixer volume | 5 mL | Nominal; Configuration-specific | Source 1 · Configuration table / solvent delivery / mixer / selected column |
| Sample valve | Software-switched load, sample-to-column and waste positions; fixed-volume sample loop | Nominal; Configuration-specific | Source 1 · Configuration table / sample module / sample valve |
| Column-position valve | Forward and reverse flushing; bypass | Nominal; Configuration-specific | Source 1 · Configuration table / separation module / column-position valve |
| UV detector | Any two wavelengths at once within 190–400 nm; wavelength accuracy and repeatability ±1 nm | Nominal; Configuration-specific | Source 1 · Configuration table / detection module / UV detector |
| Conductivity detector | Accuracy ±2 %; integrated temperature sensor | Nominal; Measuring range is not stated consistently by the sources and is omitted. Configuration-specific | Source 1 · Configuration table / detection module / conductivity detector and temperature sensor |
| pH detector | pH 0–14; accuracy ±0.05 | Nominal; Configuration-specific | Source 1 · Configuration table / detection module / pH detector |
| Power and outline dimensions | 2000 W; 616 × 544 × 673 mm | Nominal; The axis order of the dimensions is not stated by the source. Configuration-specific | Source 1 · Configuration table / system outline / power and dimensions / selected column |
Specification sources
- Specification source 1Document SHA-256:
16338757d69e3d13783d7c8c1eaf6fb12805adecfc1bf60795d46d2c591889c2
Source documents are supplied with the quotation on request.
Configure your system
Options
Discuss your requirements when requesting a quotation.
Complete your setup
Accessories
Discuss your requirements when requesting a quotation.
Your requirements
Discuss your configuration
Include the model, required configuration and accessories in your enquiry.