Skip to content

Peptas Instruments / Preparative HPLC system

Peptas Instruments HPP-1009 Preparative liquid chromatography system

Preparative HPLC system

Made to order. Quote on request.

Request a quotation Explore specifications
Generic technical illustration of a preparative liquid chromatography system.
Illustrative render — shown for illustration only.

Key features

Technical detail

Specifications

Values are shown with their stated basis and source.

HPP-1009 technical specifications
ParameterSpecificationBasis / conditionsSource
Flow setting range0.01–40.00 mL/min; setting increment 0.01 mL/minNominal; Configuration-specificSource 1 · Specification table / clean row 1 / Flow setting range
Flow accuracy≤±1.0%Nominal; Configuration-specificSource 1 · Specification table / clean row 2 / Flow accuracy
Flow stabilityRSD ≤0.2%Nominal; Configuration-specificSource 1 · Specification table / clean row 3 / Flow stability
High operating pressure≥30 MPaNominal; The source states a lower bound for high operating pressure; this is not relabelled as a maximum. Configuration-specificSource 1 · Specification table / clean row 4 / High operating pressure
Light sourceDeuterium lampNominal; Configuration-specificSource 1 · Specification table / clean row 5 / Light source
Wavelength range190–700 nmNominal; Configuration-specificSource 1 · Specification table / clean row 6 / Wavelength range
Wavelength accuracy±1 nmNominal; Configuration-specificSource 1 · Specification table / clean row 7 / Wavelength accuracy
Wavelength repeatability≤0.1 nmNominal; Configuration-specificSource 1 · Specification table / clean row 8 / Wavelength repeatability
Software languages and operating systemChinese and English; Windows 10 and laterNominal; Configuration-specificSource 1 · Specification table / clean row 9 / Software languages and operating system
Report formatsCustom reports combining selected items, or report templatesNominal; Configuration-specificSource 1 · Specification table / clean row 10 / Report formats
User managementAdministrator, reviewer and analyst roles; permissions for settings, creation, editing, viewing and controlNominal; Configuration-specificSource 1 · Specification table / clean row 11 / User management
Specification sources
  1. Specification source 1Document SHA-256: fff73a3094154d9f3363875322df8c2103f16836429f87859a47ce250b878fca

Source documents are supplied with the quotation on request.

Configure your system

Options

Discuss your requirements when requesting a quotation.

Complete your setup

Accessories

Discuss your requirements when requesting a quotation.

Your requirements

Discuss your configuration

Include the model, required configuration and accessories in your enquiry.