Peptas Instruments / Preparative HPLC system
Peptas Instruments HPP-1003 Semi-preparative HPLC with UV detection, 50 mL/min class
Preparative HPLC system
Made to order. Quote on request.
Request a quotation Explore specificationsKey features
- Flow-rate range: 0.01–49.99 mL/minNominal; Selected column of the configuration table. Configuration-specific
- Flow output error: ±1 %Nominal; The source cites a national test standard without stating test conditions. Configuration-specific
- Flow stability: 0.1 %Maximum; The source cites a national test standard without stating test conditions; not relabelled as RSD. Configuration-specific
Technical detail
Specifications
Values are shown with their stated basis and source.
| Parameter | Specification | Basis / conditions | Source |
|---|---|---|---|
| Flow-rate range | 0.01–49.99 mL/min | Nominal; Selected column of the configuration table. Configuration-specific | Source 1 · Configuration table / infusion unit / flow rate / selected column |
| Flow output error | ±1 % | Nominal; The source cites a national test standard without stating test conditions. Configuration-specific | Source 1 · Configuration table / infusion unit / flow output error / selected column |
| Flow stability | 0.1 % | Maximum; The source cites a national test standard without stating test conditions; not relabelled as RSD. Configuration-specific | Source 1 · Configuration table / infusion unit / flow stability / selected column |
| System pressure limit | 30 MPa | Maximum; System limit; no pressure-versus-flow envelope is stated. Configuration-specific | Source 1 · Configuration table / infusion unit / system pressure / selected column |
| Pressure pulsation | 0.2 MPa | Maximum; Test conditions are not stated by the source. Configuration-specific | Source 1 · Configuration table / infusion unit / pressure pulsation / selected column |
| Pump-head material | 316L as standard; PEEK, PCTFE or titanium alloy optional | Nominal; Pump-head material only; not a statement about every wetted component. Configuration-specific | Source 1 · Configuration table / note below the table / pump head |
| Detector | UV detector as standard; single- or dual-wavelength mode selectable | Nominal; Standard detector type. Configuration-specific | Source 1 · Configuration table / detection unit / wavelength range and note below the table |
| UV wavelength range | 190–400 nm | Nominal; Selected UV range; the extended-range variant is not included. Configuration-specific | Source 1 · Configuration table / detection unit / wavelength range |
| Lamp | Deuterium; tungsten lamp optional | Nominal; Configuration-specific | Source 1 · Configuration table / detection unit / light source |
| Wavelength accuracy | ±1 nm | Nominal; Test conditions are not stated by the source. Configuration-specific | Source 1 · Configuration table / detection unit / wavelength accuracy |
| Wavelength precision | ±0.1 nm | Nominal; Test conditions are not stated by the source. Configuration-specific | Source 1 · Configuration table / detection unit / wavelength precision |
| Detector absorbance range | 0–3 AU | Nominal; Stated detector range. Configuration-specific | Source 1 · Configuration table / detection unit / absorbance range |
| Column inner diameter | 10, 20 or 30 mm | Nominal; Separation unit of this configuration, as stated by the source. Configuration-specific | Source 1 · Configuration table / separation unit / inner diameter / selected column |
| Recommended column type | Pre-packed columns | Nominal; Recommendation as stated by the source. Configuration-specific | Source 1 · Configuration table / separation unit / recommended column type / selected column |
| Sample introduction | Six-port sample valve | Nominal; Configuration-specific | Source 1 · Configuration table / sample unit / selected column |
| Fraction collection (optional unit) | Collection by retention time, by response value or manually, among other modes | Nominal; Optional fraction collection unit; not standard equipment. Configuration-specific | Source 1 · Configuration table / optional fraction collection unit |
Specification sources
- Specification source 1Document SHA-256:
d57a5e86590e90853176ed288d57c329f66647fb1e2292542e2493e715b285b3
Source documents are supplied with the quotation on request.
Configure your system
Options
Discuss your requirements when requesting a quotation.
Complete your setup
Accessories
Discuss your requirements when requesting a quotation.
Your requirements
Discuss your configuration
Include the model, required configuration and accessories in your enquiry.