- Flow-rate range: 0.01–299.99 mL/minNominal; Configuration-specific
- Flow output error: ±1 %Nominal; The source cites a national test standard without stating test conditions. Configuration-specific
- Flow stability: 0.5 %Maximum; The source cites a national test standard without stating test conditions; not relabelled as RSD. Configuration-specific
Technical detail
Specifications
Values are shown with their stated basis and source.
| Parameter | Specification | Basis / conditions | Source |
|---|---|---|---|
| Flow-rate range | 0.01–299.99 mL/min | Nominal; Configuration-specific | Source 1 · Technical table 1 / row 3 / cell 5 |
| Flow output error | ±1 % | Nominal; The source cites a national test standard without stating test conditions. Configuration-specific | Source 1 · Technical table 1 / row 4 / cell 5 |
| Flow stability | 0.5 % | Maximum; The source cites a national test standard without stating test conditions; not relabelled as RSD. Configuration-specific | Source 1 · Technical table 1 / row 5 / cell 5 |
| System pressure limit | 15 MPa | Maximum; Configuration-specific | Source 1 · Technical table 1 / row 6 / cell 5 |
| Pressure pulsation | 0.5 MPa | Maximum; Configuration-specific | Source 1 · Technical table 1 / row 7 / cell 5 |
| Pump-head material | 316L | Nominal; Standard pump head, as stated by the source; Configuration-specific | Source 1 · Technical table 1 / row 22 / cell 1 |
| Detector | UV | Nominal; Standard detector type. Configuration-specific | Source 1 · Technical table 1 / row 22 / cell 1 |
| Wavelength range | 190–400 nm | Nominal; Configuration-specific | Source 1 · Technical table 1 / row 9 / cell 2 |
| Wavelength accuracy | ±1 nm | Nominal; Configuration-specific | Source 1 · Technical table 1 / row 11 / cell 2 |
| Detector absorbance range | 0–3 AU | Nominal; Stated detector range. Configuration-specific | Source 1 · Technical table 1 / row 15 / cell 2 |
Specification sources
- Specification source 1Document SHA-256:
52b64570b074e811c1227d10fb3bf7ddd1cb19f65b6f383133d09dcaccf4d1c7
Source documents are supplied with the quotation on request.