Peptas Instruments HPP-1001 Laboratory preparative HPLC with UV detection

Preparative HPLC system

Made to order. Quote on request.

Request a quotation Explore specifications
Generic technical illustration of a preparative chromatography system.
Illustrative render — shown for illustration only.

Key features

Technical detail

Specifications

Values are shown with their stated basis and source.

HPP-1001 technical specifications
ParameterSpecificationBasis / conditionsSource
Flow-rate range0.01–99.99 mL/minNominal; Selected laboratory pump configuration.; Configuration-specificSource 1 · Configuration table / selected flow column
System pressure limit20 MPaMaximum; Selected 100 mL/min class configuration; source specifies an upper pressure limit.; Configuration-specificSource 1 · Configuration table / system pressure
Flow output error±1%Nominal; Detailed test conditions are not provided in the source.; Configuration-specificSource 1 · Configuration table / flow output error
Flow stability0.1 %Maximum; Detailed test conditions are not provided in the source; not relabelled as RSD.; Configuration-specificSource 1 · Configuration table / flow stability
Pressure pulsation0.2 MPaMaximum; Selected laboratory pump configuration.; Configuration-specificSource 1 · Configuration table / pressure pulsation
Pump-head material316L stainless steelNominal; Standard pump head; this is not a claim about every wetted component.; Configuration-specificSource 1 · Configuration table / pump-head note
Detector configurationDual-wavelength UVNominal; Selected dual-wavelength option; other optical configurations remain separate.; Configuration-specificSource 1 · Detection unit / configuration
UV wavelength range190–400 nmNominal; Selected UV configuration; the extended visible-range option is not included.; Configuration-specificSource 1 · Detection unit / wavelength options
Wavelength accuracy±1 nmNominal; Stated detector value; test conditions are not provided.; Configuration-specificSource 1 · Detection unit / wavelength accuracy
Detector absorbance range0–3 AUNominal; Stated detector range.; Configuration-specificSource 1 · Detection unit / absorbance range
Automatic fraction collectionRetention-time, response-threshold and manual collectionNominal; Optional automatic fraction collector selected for quotation; not standard equipment.; Configuration-specificSource 1 · Optional fraction collection / collection modes
Specification sources
  1. Specification source 1Document SHA-256: fce08a09a53e06fc3653fe4c4967ca3a8127535930948cf8f2e5d441d6844ee8

Source documents are supplied with the quotation on request.

Configure your system

Options

  • Automatic fraction collector selected for quotation; collection by retention time, response threshold or manual control. Source 1
  • Alternative pump-head materials can be specified in the enquiry. Source 1