Peptas Instruments / Preparative HPLC system
Peptas Instruments HPP-1001 Laboratory preparative HPLC with UV detection
Preparative HPLC system
Made to order. Quote on request.
Request a quotation Explore specificationsKey features
- Flow-rate range: 0.01–99.99 mL/minNominal; Selected laboratory pump configuration.; Configuration-specific
- System pressure limit: 20 MPaMaximum; Selected 100 mL/min class configuration; source specifies an upper pressure limit.; Configuration-specific
- Flow output error: ±1%Nominal; Detailed test conditions are not provided in the source.; Configuration-specific
Technical detail
Specifications
Values are shown with their stated basis and source.
| Parameter | Specification | Basis / conditions | Source |
|---|---|---|---|
| Flow-rate range | 0.01–99.99 mL/min | Nominal; Selected laboratory pump configuration.; Configuration-specific | Source 1 · Configuration table / selected flow column |
| System pressure limit | 20 MPa | Maximum; Selected 100 mL/min class configuration; source specifies an upper pressure limit.; Configuration-specific | Source 1 · Configuration table / system pressure |
| Flow output error | ±1% | Nominal; Detailed test conditions are not provided in the source.; Configuration-specific | Source 1 · Configuration table / flow output error |
| Flow stability | 0.1 % | Maximum; Detailed test conditions are not provided in the source; not relabelled as RSD.; Configuration-specific | Source 1 · Configuration table / flow stability |
| Pressure pulsation | 0.2 MPa | Maximum; Selected laboratory pump configuration.; Configuration-specific | Source 1 · Configuration table / pressure pulsation |
| Pump-head material | 316L stainless steel | Nominal; Standard pump head; this is not a claim about every wetted component.; Configuration-specific | Source 1 · Configuration table / pump-head note |
| Detector configuration | Dual-wavelength UV | Nominal; Selected dual-wavelength option; other optical configurations remain separate.; Configuration-specific | Source 1 · Detection unit / configuration |
| UV wavelength range | 190–400 nm | Nominal; Selected UV configuration; the extended visible-range option is not included.; Configuration-specific | Source 1 · Detection unit / wavelength options |
| Wavelength accuracy | ±1 nm | Nominal; Stated detector value; test conditions are not provided.; Configuration-specific | Source 1 · Detection unit / wavelength accuracy |
| Detector absorbance range | 0–3 AU | Nominal; Stated detector range.; Configuration-specific | Source 1 · Detection unit / absorbance range |
| Automatic fraction collection | Retention-time, response-threshold and manual collection | Nominal; Optional automatic fraction collector selected for quotation; not standard equipment.; Configuration-specific | Source 1 · Optional fraction collection / collection modes |
Specification sources
- Specification source 1Document SHA-256:
fce08a09a53e06fc3653fe4c4967ca3a8127535930948cf8f2e5d441d6844ee8
Source documents are supplied with the quotation on request.