HPF-1002 technical specifications
ParameterSpecificationBasis / conditionsSource
Solvent selectionFour-channel solvent selectionNominal; Configuration-specificSource 1 · Configuration table / solvent delivery / channels
Pump typeHigh-precision metering pumpNominal; Configuration-specificSource 1 · Configuration table / solvent delivery / pump / selected column
Flow-rate range1–200 mL/minNominal; Configuration-specificSource 1 · Configuration table / solvent delivery / flow range / selected column
Maximum pressure200 psiMaximum; Stated in psi by the source; not converted here. Configuration-specificSource 1 · Configuration table / solvent delivery / maximum pressure / selected column
Flow accuracy±2 %Nominal; Test conditions are not stated by the source. Configuration-specificSource 1 · Configuration table / solvent delivery / flow accuracy / selected column
Gradient modesIsocratic, or gradient (linear or step)Nominal; Configuration-specificSource 1 · Configuration table / solvent delivery / gradient form
Static mixer volume15 mLNominal; Configuration-specificSource 1 · Configuration table / solvent delivery / mixer
Wetted materials316L stainless steel (S31603), PEEK and PTFENominal; Configuration-specificSource 1 · Configuration table / solvent delivery / wetted materials
Sample loadingLiquid or solid sample loadingNominal; Configuration-specificSource 1 · Configuration table / sample module / loading method
Column rackAccepts 4 g to 330 g separation columns; expandable to 800 gNominal; Configuration-specificSource 1 · Configuration table / sample module / column rack
DetectorDiode-array detector, 200–400 nm or 200–800 nm, full-range scanning, 0.3 mm flow cell, wavelength accuracy ±1 nmNominal; Two detector range options, as stated by the source. Configuration-specificSource 1 · Configuration table / detection module / diode-array detector (two rows)
Collection modesThreshold, full and waste collectionNominal; Configuration-specificSource 1 · Configuration table / collection module / collection form
Collection tube racks13, 15, 16, 18, 25 and 30 mm tubes; custom containersNominal; Configuration-specificSource 1 · Configuration table / collection module / tube rack sizes
Liquid-level monitoringSolvent level and waste-bottle levelNominal; Configuration-specificSource 1 · Configuration table / gas-path module / liquid-level monitoring
Operation15-inch touch screenNominal; Configuration-specificSource 1 · Configuration table / operation module / operating mode
Specification sources
  1. Specification source 1Document SHA-256: 9009bf4cc62b852dddf1f5a83c776b637db7f66e65e14079b7105635a02d5c20

Source documents are supplied with the quotation on request.

Configure your system

Options

Discuss your requirements when requesting a quotation.

Complete your setup

Accessories

Discuss your requirements when requesting a quotation.

Your requirements

Discuss your configuration

Include the model, required configuration and accessories in your enquiry.

Request a quotation