Request a quotation Explore specificationsKey features
- Solvent selection: Four-channel solvent selectionNominal; Configuration-specific
- Pump type: High-precision plunger pumpNominal; Configuration-specific
- Flow-rate range: 1–300 mL/minNominal; Configuration-specific
Technical detail
Specifications
Values are shown with their stated basis and source.
| Parameter | Specification | Basis / conditions | Source |
|---|---|---|---|
| Solvent selection | Four-channel solvent selection | Nominal; Configuration-specific | Source 1 · Configuration table / solvent delivery / channels |
| Pump type | High-precision plunger pump | Nominal; Configuration-specific | Source 1 · Configuration table / solvent delivery / pump / selected column |
| Flow-rate range | 1–300 mL/min | Nominal; Configuration-specific | Source 1 · Configuration table / solvent delivery / flow range / selected column |
| Maximum pressure | 500 psi | Maximum; Stated in psi by the source; not converted here. Configuration-specific | Source 1 · Configuration table / solvent delivery / maximum pressure / selected column |
| Flow accuracy | ±1 % | Nominal; Test conditions are not stated by the source. Configuration-specific | Source 1 · Configuration table / solvent delivery / flow accuracy / selected column |
| Gradient modes | Isocratic, or gradient (linear or step) | Nominal; Configuration-specific | Source 1 · Configuration table / solvent delivery / gradient form |
| Static mixer volume | 15 mL | Nominal; Configuration-specific | Source 1 · Configuration table / solvent delivery / mixer |
| Wetted materials | 316L stainless steel (S31603), PEEK and PTFE | Nominal; Configuration-specific | Source 1 · Configuration table / solvent delivery / wetted materials |
| Sample loading | Liquid or solid sample loading | Nominal; Configuration-specific | Source 1 · Configuration table / sample module / loading method |
| Column rack | Accepts 4 g to 330 g separation columns; expandable to 800 g | Nominal; Configuration-specific | Source 1 · Configuration table / sample module / column rack |
| Detector | Diode-array detector, 200–400 nm or 200–800 nm, full-range scanning, 0.3 mm flow cell, wavelength accuracy ±1 nm | Nominal; Two detector range options, as stated by the source. Configuration-specific | Source 1 · Configuration table / detection module / diode-array detector (two rows) |
| Collection modes | Threshold, full and waste collection | Nominal; Configuration-specific | Source 1 · Configuration table / collection module / collection form |
| Collection tube racks | 13, 15, 16, 18, 25 and 30 mm tubes; custom containers | Nominal; Configuration-specific | Source 1 · Configuration table / collection module / tube rack sizes |
| Liquid-level monitoring | Solvent level and waste-bottle level | Nominal; Configuration-specific | Source 1 · Configuration table / gas-path module / liquid-level monitoring |
| Operation | 15-inch touch screen | Nominal; Configuration-specific | Source 1 · Configuration table / operation module / operating mode |
Specification sources
- Specification source 1Document SHA-256:
9009bf4cc62b852dddf1f5a83c776b637db7f66e65e14079b7105635a02d5c20
Source documents are supplied with the quotation on request.
Configure your system
Options
Discuss your requirements when requesting a quotation.
Complete your setup
Accessories
Discuss your requirements when requesting a quotation.
Your requirements
Discuss your configuration