Peptas Instruments / Analytical HPLC system

Peptas Instruments HPA-1007 Analytical liquid chromatography system

Analytical HPLC system

Made to order. Quote on request.

Request a quotation Explore specifications
Generic technical illustration of an analytical liquid chromatography system.
Illustrative render — shown for illustration only.

Key features

Technical detail

Specifications

Values are shown with their stated basis and source.

HPA-1007 technical specifications
ParameterSpecificationBasis / conditionsSource
Flow range0.001-10.000 mL/min, Increment: 0.001 mL/minNominal; Configuration-specificSource 1 · Specification table / clean row 1 / Flow range
Flow accuracy≤ ±0.3%Nominal; Configuration-specificSource 1 · Specification table / clean row 2 / Flow accuracy
Flow stability≤ 0.085%Nominal; Configuration-specificSource 1 · Specification table / clean row 3 / Flow stability
Pressure pulsation1%Nominal; Configuration-specificSource 1 · Specification table / clean row 4 / Pressure pulsation
Carryover< 0.005%Nominal; Configuration-specificSource 1 · Specification table / clean row 5 / Carryover
Sample tray configuration120 positions × 2 mLNominal; Configuration-specificSource 1 · Specification table / clean row 6 / Sample tray configuration
Temperature control range5 °C above ambient to 99 ℃Nominal; Configuration-specificSource 1 · Specification table / clean row 7 / Temperature control range
Temperature accuracy±0.5 ℃Nominal; Configuration-specificSource 1 · Specification table / clean row 8 / Temperature accuracy
Column capacity2 × 300 mm columnsNominal; Configuration-specificSource 1 · Specification table / clean row 9 / Column capacity
Light sourceDeuterium lampNominal; Configuration-specificSource 1 · Specification table / clean row 10 / Light source
Wavelength range190-700 nmNominal; Configuration-specificSource 1 · Specification table / clean row 11 / Wavelength range
Spectral bandwidth8 nmNominal; Configuration-specificSource 1 · Specification table / clean row 12 / Spectral bandwidth
Wavelength accuracy±1 nmNominal; Configuration-specificSource 1 · Specification table / clean row 13 / Wavelength accuracy
Baseline drift1.5 × 10⁻⁴ AU/hNominal; Configuration-specificSource 1 · Specification table / clean row 14 / Baseline drift
Noise±1.0 × 10⁻⁵ AUNominal; Configuration-specificSource 1 · Specification table / clean row 15 / Noise
Specification sources
  1. Specification source 1Document SHA-256: 781174c7d6e02233aca416cf5fd0c0904ed5075c6af3bdcf841f300c9a1bef8c

Source documents are supplied with the quotation on request.