Peptas Instruments HPA-1005 Analytical liquid chromatography system

Analytical HPLC system

Made to order. Quote on request.

Request a quotation Explore specifications
Generic technical illustration of a analytical liquid chromatography system.
Illustrative render — shown for illustration only.

Key features

Technical detail

Specifications

Values are shown with their stated basis and source.

HPA-1005 technical specifications
ParameterSpecificationBasis / conditionsSource
Pump — Flow range0.001–9.999 mL/min; setting increment 0.001 mL/minNominal; Configuration-specificSource 1 · Specification table / clean row 1 / Pump — Flow range
Pump — Flow stability errorSr ≤±0.3%; RSD <±0.06%Nominal; Sr and RSD notation reproduced as printed; no correction to the source notation. Configuration-specificSource 1 · Specification table / clean row 2 / Pump — Flow stability error
Pump — Flow setting errorSs ≤±0.5%Nominal; Water at 1 mL/min, 5–10 MPa, room temperature. Configuration-specificSource 1 · Specification table / clean row 3 / Pump — Flow setting error
Pump — Pressure linearity and accuracyDisplayed pressure error ≤±0.5 MPa over 0–42 MPaNominal; Configuration-specificSource 1 · Specification table / clean row 4 / Pump — Pressure linearity and accuracy
Pump — Pressure pulsation≤0.1 MPaNominal; Flow 1 mL/min; pressure 5–10 MPa. Configuration-specificSource 1 · Specification table / clean row 5 / Pump — Pressure pulsation
Pump — Pressure retention test42 MPa for 10 min; pressure drop <0.5 MPaNominal; Configuration-specificSource 1 · Specification table / clean row 6 / Pump — Pressure retention test
Pump — High operating pressure42 MPaNominal; Flow range 0.001–9.999 mL/min. Configuration-specificSource 1 · Specification table / clean row 7 / Pump — High operating pressure
Pump — Dimensions (L × W × H)450 × 300 × 160 mmNominal; Configuration-specificSource 1 · Specification table / clean row 8 / Pump — Dimensions (L × W × H)
UV detector — Wavelength range190–680 nmNominal; Configuration-specificSource 1 · Specification table / clean row 9 / UV detector — Wavelength range
UV detector — Spectral bandwidth8 nmNominal; Configuration-specificSource 1 · Specification table / clean row 10 / UV detector — Spectral bandwidth
UV detector — Wavelength indication error≤±1 nmNominal; Configuration-specificSource 1 · Specification table / clean row 11 / UV detector — Wavelength indication error
UV detector — Baseline noise≤2×10^-5 AUNominal; Dynamic measurement. Configuration-specificSource 1 · Specification table / clean row 12 / UV detector — Baseline noise
UV detector — Baseline drift≤2×10^-4 AUNominal; Dynamic measurement; no time denominator is stated in the clean source row. Configuration-specificSource 1 · Specification table / clean row 13 / UV detector — Baseline drift
UV detector — Minimum detection concentration1×10^-8 g/mLNominal; Naphthalene in methanol. Configuration-specificSource 1 · Specification table / clean row 14 / UV detector — Minimum detection concentration
UV detector — Dimensions (L × W × H)450 × 300 × 160 mmNominal; Configuration-specificSource 1 · Specification table / clean row 15 / UV detector — Dimensions (L × W × H)
Specification sources
  1. Specification source 1Document SHA-256: e4fefdef421973fe59983948eca800ff96207120a5a8223920aa3c37de032ba5

Source documents are supplied with the quotation on request.