Key features

Technical detail

Specifications

Values are shown with their stated basis and source.

HPA-1004 technical specifications
ParameterSpecificationBasis / conditionsSource
Pump — Maximum Operating Pressure62MPa/75MPaNominal; Specification for the pump section of the source table; no claim that all listed modules are included together. Configuration-specificSource 1 · Specification table / clean row 1 / Pump — Maximum Operating Pressure
Pump — Flow Rate Setting Range0.0000–12.0000mL/minNominal; Specification for the pump section of the source table; no claim that all listed modules are included together. Configuration-specificSource 1 · Specification table / clean row 2 / Pump — Flow Rate Setting Range
Pump — Flow Rate Setting Increment0.0001mL/minNominal; Specification for the pump section of the source table; no claim that all listed modules are included together. Configuration-specificSource 1 · Specification table / clean row 3 / Pump — Flow Rate Setting Increment
Pump — Gradient Error≤ 0.75%Nominal; Specification for the pump section of the source table; no claim that all listed modules are included together. Configuration-specificSource 1 · Specification table / clean row 4 / Pump — Gradient Error
Pump — Gradient Stability0.2% RSD (5% to 95%, 0.2 to 2.0 mL/min)Nominal; Specification for the pump section of the source table; no claim that all listed modules are included together. Test/configuration note: 5% to 95%, 0.2 to 2.0 mL/min. Configuration-specificSource 1 · Specification table / clean row 5 / Pump — Gradient Stability
Pump — Flow setting error±0.20%Nominal; Specification for the pump section of the source table; no claim that all listed modules are included together. Configuration-specificSource 1 · Specification table / clean row 6 / Pump — Flow setting error
Pump — Flow Rate Stability≤0.075% RSDNominal; Specification for the pump section of the source table; no claim that all listed modules are included together. Configuration-specificSource 1 · Specification table / clean row 7 / Pump — Flow Rate Stability
Autosampler — Sample Introduction Volume100μL, 200μL, 500μL, 1000μL, 1500μL, 2000 μLNominal; Specification for the autosampler section of the source table; no claim that all listed modules are included together. Configuration-specificSource 1 · Specification table / clean row 8 / Autosampler — Sample Introduction Volume
Autosampler — Repeatability<0.3%RSD (2μL–Max), <1.0%RSD (0.1μL–1.9μL);Nominal; Specification for the autosampler section of the source table; no claim that all listed modules are included together. Configuration-specificSource 1 · Specification table / clean row 9 / Autosampler — Repeatability
Autosampler — Linear Correlation Coefficient>0.9999Nominal; Specification for the autosampler section of the source table; no claim that all listed modules are included together. Configuration-specificSource 1 · Specification table / clean row 10 / Autosampler — Linear Correlation Coefficient
Autosampler — Sample positions108 (2*54, 2mL), 96-well platesNominal; Specification for the autosampler section of the source table; no claim that all listed modules are included together. Configuration-specificSource 1 · Specification table / clean row 11 / Autosampler — Sample positions
Autosampler — Temperature Setting Range4.0–35.0°C (optional refrigeration)Nominal; Specification for the autosampler section of the source table; no claim that all listed modules are included together. Test/configuration note: optional refrigeration. Configuration-specificSource 1 · Specification table / clean row 12 / Autosampler — Temperature Setting Range
Autosampler — Temperature Setting Value Error±0.5°C (optional refrigeration);Nominal; Specification for the autosampler section of the source table; no claim that all listed modules are included together. Test/configuration note: optional refrigeration. Configuration-specificSource 1 · Specification table / clean row 13 / Autosampler — Temperature Setting Value Error
Autosampler — Temperature Stability±1°C (optional refrigeration)Nominal; Specification for the autosampler section of the source table; no claim that all listed modules are included together. Test/configuration note: optional refrigeration. Configuration-specificSource 1 · Specification table / clean row 14 / Autosampler — Temperature Stability
Column oven — Temperature Setting Range4°C-90°CNominal; Specification for the column oven section of the source table; no claim that all listed modules are included together. Configuration-specificSource 1 · Specification table / clean row 15 / Column oven — Temperature Setting Range
Column oven — Temperature Stability±0.03°C/hNominal; Specification for the column oven section of the source table; no claim that all listed modules are included together. Configuration-specificSource 1 · Specification table / clean row 16 / Column oven — Temperature Stability
Column oven — Temperature Setting Value Error±0.1°CNominal; Specification for the column oven section of the source table; no claim that all listed modules are included together. Configuration-specificSource 1 · Specification table / clean row 17 / Column oven — Temperature Setting Value Error
UV detector — Baseline Noise≤8.0×10⁻⁶ Au (1mL/min, methanol, C18)Nominal; Specification for the uv detector section of the source table; no claim that all listed modules are included together. Test/configuration note: 1mL/min, methanol, C18. Configuration-specificSource 1 · Specification table / clean row 18 / UV detector — Baseline Noise
UV detector — Baseline Drift≤1.0×10⁻⁴ AU/h (1mL/min, methanol, C18)Nominal; Specification for the uv detector section of the source table; no claim that all listed modules are included together. Test/configuration note: 1mL/min, methanol, C18. Configuration-specificSource 1 · Specification table / clean row 19 / UV detector — Baseline Drift
UV detector — Minimum detection concentration≤5×10⁻⁹ g/mL (naphthalene/methanol)Nominal; Specification for the uv detector section of the source table; no claim that all listed modules are included together. Test/configuration note: naphthalene/methanol. Configuration-specificSource 1 · Specification table / clean row 20 / UV detector — Minimum detection concentration
UV detector — Spectral Range188-900nmNominal; Specification for the uv detector section of the source table; no claim that all listed modules are included together. Configuration-specificSource 1 · Specification table / clean row 21 / UV detector — Spectral Range
UV detector — Wavelength Error≤ ±1nmNominal; Specification for the uv detector section of the source table; no claim that all listed modules are included together. Configuration-specificSource 1 · Specification table / clean row 22 / UV detector — Wavelength Error
UV detector — Wavelength Repeatability≤ ±0.1nmNominal; Specification for the uv detector section of the source table; no claim that all listed modules are included together. Configuration-specificSource 1 · Specification table / clean row 23 / UV detector — Wavelength Repeatability
UV detector — Linear Range≥1×10⁴ or 2.5AuNominal; Specification for the uv detector section of the source table; no claim that all listed modules are included together. Configuration-specificSource 1 · Specification table / clean row 24 / UV detector — Linear Range
Specification sources
  1. Specification source 1Document SHA-256: ed5c7c0b41aba10588ce65a29e72d0dfc2ba0f27b2e035b06377e69e90c50087

Source documents are supplied with the quotation on request.

Configure your system

Options

Discuss your requirements when requesting a quotation.

Complete your setup

Accessories

Discuss your requirements when requesting a quotation.

Your requirements

Discuss your configuration

Include the model, required configuration and accessories in your enquiry.

Request a quotation