Peptas Instruments / Analytical HPLC system
Peptas Instruments HPA-1001 Quaternary analytical HPLC with diode-array detection
Analytical HPLC system
Made to order. Quote on request.
Request a quotation Explore specificationsKey features
- Pump configuration: QuaternaryNominal; Selected four-solvent pump configuration.; Configuration-specific
- Maximum pump pressure: 70 MPaMaximum; Selected quaternary pump; not a binary-pump rating.; Configuration-specific
- Detector: Photodiode array (PDA / DAD)Nominal; Selected detector configuration.; Configuration-specific
Technical detail
Specifications
Values are shown with their stated basis and source.
| Parameter | Specification | Basis / conditions | Source |
|---|---|---|---|
| Pump configuration | Quaternary | Nominal; Selected four-solvent pump configuration.; Configuration-specific | Source 1 · Infusion system / quaternary pump |
| Maximum pump pressure | 70 MPa | Maximum; Selected quaternary pump; not a binary-pump rating.; Configuration-specific | Source 1 · Quaternary pump / pressure |
| Detector | Photodiode array (PDA / DAD) | Nominal; Selected detector configuration.; Configuration-specific | Source 1 · Detector / diode-array section |
| Detector wavelength range | 200–800 nm | Nominal; Selected diode-array detector.; Configuration-specific | Source 1 · Diode-array detector / wavelength |
| Wavelength setting increment | 1 nm | Nominal; Selected diode-array detector.; Configuration-specific | Source 1 · Diode-array detector / wavelength increment |
| Detector acquisition frequency | 100 Hz | Nominal; Spectral scanning or absorbance measurement under eight wavelengths, as stated in the specification.; Configuration-specific | Source 1 · Diode-array detector / acquisition |
| Simultaneous detector wavelengths | 8 | Nominal; Selected diode-array detector at the stated acquisition frequency.; Configuration-specific | Source 1 · Diode-array detector / acquisition |
| Three-dimensional spectral display | Yes | Nominal; Selected diode-array detector.; Configuration-specific | Source 1 · Diode-array detector / spectral display |
Specification sources
- Specification source 1Document SHA-256:
ded55c361bfb4eff6388d3a30ab51429bf3be6c168e62eb49f81d0bb3dad2fff
Source documents are supplied with the quotation on request.
Configure your system
Options
- Autosampler refrigeration option; specify the required configuration in the enquiry. Source 1
Complete your setup
Accessories
Discuss your requirements when requesting a quotation.
Your requirements
Discuss your configuration
Include the model, required configuration and accessories in your enquiry.